CWI Exam · Part C · Code Application

CWI Practice Questions — D1.1 Code Application

CWI Part C試験では、時間的制約のある中で溶接基準を読み解き、適用する能力が試されます。これらの練習問題は、D1.1:2025基準の適用、すなわち予熱の確認、すみ肉溶接サイズの決定、事前認定規則、および重要変数に焦点を当てています。各解答には、特定の条項または表の参照が記載されています。

これらの質問の利用方法: シナリオを読み、解答を試み、その後解答を確認してください。各解答には、特定のD1.1条項または表が引用されています。難しいと感じるトピックについては、上記のFluxを使用して追加の質問をしてください。

予熱 — 表 5.11

Q1: A572 Gr.50 plate, 1 inch thick, welded with FCAW using E71T-1. What is the 最小 予熱?
Answer: 50°F (10°C). A572 Gr.50 is Group II in Table 5.11. E71T-1 is a 低水素 電極, placing it in カテゴリー B. For Group II, Category B, 板厚 over 3/4 through 1-1/2 inch: minimum preheat is 50°F.
Q2: Same steel and thickness, but the 溶接士 switches to E71T-11 (self-shielded FCAW). Does the preheat change?
Answer: Yes — dramatically. E71T-11 is a 非低水素 electrode, moving the WPS to Category A in Table 5.11. For Group II, Category A, 1 inch thickness: minimum preheat jumps to 150°F (65°C). This is a common exam trap — the only change is the 電極分類, but the preheat triples.

すみ肉溶接サイズ — 表 7.7

Q3: You are 溶接 a 1/2-inch plate to a 3/4-inch plate using E7018 (SMAW). What is the minimum すみ肉溶接サイズ per 表 7.7?
Answer: 3/16 inch. Per Table 7.7 Footnote A, when using a low-hydrogen process (E7018), T equals the thinner part joined (1/2 inch). For T over 1/4 through 1/2 inch, すみ肉最小サイズ is 3/16 inch. If the welder used a non-low-hydrogen process without preheat, T would equal the thicker part (3/4 inch), requiring 1/4 inch minimum.
Q4: The Engineer specifies a 3/16-inch すみ肉溶接 on 1-1/4-inch thick A36 plate using E6013 without preheat. Is this acceptable?
Answer: No. E6013 is a non-low-hydrogen electrode, so per Table 7.7 Footnote A, T equals the thicker part (1-1/4 inch). For T over 3/4 inch, minimum fillet サイズ is 5/16 inch. The 3/16-inch 溶接 is undersized. Additionally, Table 5.11 requires 150°F preheat for Group I, Category A at this thickness (over 3/4 thru 1-1/2 inch) — but the scenario says no preheat was applied, which is also non-compliant.

事前認定WPS — 条項 5

Q5: A 製作者 wants to prequalify a WPS using GMAW short-circuit transfer on 1/2-inch A36 plate. Can this be 事前認定?
Answer: No. D1.1:2025 条項 5 does not include GMAW with short-circuiting transfer (GMAW-S) from prequalification. The fabricator must qualify the procedure by 試験 under Clause 6. スプレー転移, グロビュラー転移, and pulsed-spray GMAW are prequalified when all other Clause 5 conditions are met.
Q6: Can a 事前認定WPS use a single-V groove joint with a ルート間隙 less than the D1.1 minimum?
Answer: No. Prequalified joint dimensions must conform to the tolerances shown in Figure 5.1 (CJP groove welds), Figure 5.2 (PJP groove welds), or Figure 5.3 (fillet welds). Any deviation from these prequalified joint dimensions — including root opening, 開先角度, ルート面, or land — requires WPS qualification under Clause 6.

重要変数 — 表 5.5

Q7: A fabricator changes from E7018 to E71T-1 on a prequalified WPS. Is a new WPS required?
Answer: Yes. This is a change in 溶接工程 (SMAW to FCAW), which is an 重要変数 per Table 5.5. A new prequalified WPS must be written for the FCAW process. However, since both E7018 and E71T-1 are low-hydrogen electrodes (Category B in Table 5.11), the preheat 要求事項 remain unchanged.
Q8: On a prequalified WPS, the welder changes position from 1G (flat) to 3G (vertical). Does this require a new WPS?
Answer: Yes. Position is an essential variable in Table 5.5. However, because this is a prequalified WPS, no 資格試験 is required — the fabricator simply writes a new prequalified WPS specifying the 3G position with appropriate parameters for vertical welding.

ASME IX 関連質問

Q9: A welder is qualified under ASME IX for SMAW on P-Number 1 materials. Can they weld 構造用鋼 under D1.1 with no additional testing?
Answer: No. ASME IX and D1.1 maintain completely independent qualification systems. An ASME IX WPQ does not satisfy D1.1 Clause 6 Part D 溶接技能者資格 requirements. The welder must qualify separately under D1.1. In practice, many welders hold both qualifications.
Q10: What is the key difference between ASME IX supplementary essential variables and D1.1 essential variables?
Answer: ASME IX has a three-tier system: essential, supplementary essential, and nonessential variables per the QW-250 series. Supplementary essential variables become essential only when impact testing is required by the construction code. D1.1 has only two tiers: essential (Table 5.5 for prequalified, Table 6.6 for qualified) and nonessential. There is no supplementary essential concept in D1.1.

"CWI Part C試験では、時間管理が全てです。60問のコードブック問題に2時間与えられます。これは1問あたり2分です。30秒以内に表や条項が見つからない場合は、印を付けて次に進んでください。Table 5.11Table 7.7Table 5.5Clause 5、およびClause 6に付箋を貼ってコードブックをタブ付けしてください — これらは最も頻繁に出題されるセクションです。"

— Field observation, CWI exam preparation practice

CWI試験のヒント: Part C試験では、タブ付けされ、ハイライトされたコードブック(手書きのメモなし)の持ち込みが許可されています。暗記ではなく、迅速な表の検索に焦点を当てて準備を進めてください。解答そのものを暗記するよりも、解答がどこにあるかを知っていることの方が価値があります。

関連基準ガイド

よくある質問

D1.1:2025 表 5.11によると、A572 Gr.50はグループIIに分類されます。FCAW(低水素溶接工程、カテゴリーB)の場合、3/4インチ超1-1/2インチ以下の板厚に対する最小予熱温度は50°F(10°C)です。E71T-11を使用するFCAW-Sのような非低水素溶接工程を使用する場合、鋼材はカテゴリーAに分類され、同じ厚さ範囲で150°F(65°C)が必要となります。

D1.1:2025 表 7.7によると、最小すみ肉溶接サイズは、非低水素溶接工程を予熱なしで使用する場合は接合される厚い方の板厚(T)によって決定され、低水素溶接工程を使用する場合は薄い方の板厚によって決定されます。低水素溶接工程(E7018、E71T-1、ER70S-6)の場合、Tは薄い方の板厚(1/2インチ)となり、最小3/16インチが必要です。予熱なしの非低水素溶接工程の場合、Tは厚い方の板厚(3/4インチ)となり、最小1/4インチが必要です。

いいえ。D1.1:2025では、GMAW-S(短絡移行)は事前認定溶接工程として含まれていません。短絡GMAWは、特に厚い材料において融合不良のリスクが高く、条項 6に基づく資格試験によるWPSの資格認定が必要です。他のGMAW移行モード(スプレー、グロビュラー、パルススプレー)は、Clause5の他の全ての要件が満たされている場合、事前認定されます。

E7018(SMAW、A5.1)からE71T-1(FCAW-G、A5.20)への変更は、溶接工程(SMAWからFCAW)の変更であり、D1.1 表 5.5の重要変数に該当します。この場合、新しいWPSが必要です。ただし、両方の溶接棒は低水素であり、表 5.11 カテゴリーBに分類されるため、予熱要件は同じままです。新しいFCAW WPSは、継手設計が図5.1から5.3に合致するなど、他の全ての事前認定条件が満たされていれば、条項 5の下で引き続き事前認定が可能です。

D1.1 条項 5に基づく事前認定WPSの場合、姿勢は表 5.5に重要変数として記載されています。1G(下向き)から3G(立向き)への変更には、新しいまたは改訂されたWPSが必要です。ただし、WPSが事前認定されているため、再資格試験は必要ありません。製作者は、3G姿勢を指定し、立向き溶接に適したパラメータ(通常、低電流、ウィービング技術)を記載した新しい事前認定WPSを作成するだけです。条項 6に基づく資格認定WPSの場合、溶接士も3G姿勢で性能資格認定されている必要があります。